| Peer-Reviewed

Analysis of Shading Effects in Solar PV System

Received: 10 April 2021     Accepted: 26 April 2021     Published: 8 May 2021
Views:       Downloads:
Abstract

Due to its advantages, the use of clean energy in general and especially solar PV systems offer a great solution to problems that people face in their everyday life. Generation of energy using solar PV system technology is cheaper and clean technology compared to one of the fossil fuels. Aside from its advantages, this technology still has some drawbacks that affect its performance where the ones caused by shadows are considered as one of the big problems. This research work showed laboratory experiments and simulations to see how the system is affected by shading where a 1.5 kWp PV system has been used for the study. The system has been simulated with PVsyst (7.0.6 version) and experimented within the University of Rwanda/ African Center of Excellence in Energy Studies for Sustainable Development (UR/ACE-ESD) High E-Tech Smart Grid Laboratory. Laboratory experiments showed that whatever shade is applied to the system, the DC voltage and current change (increases or decrease) and DC power decreases. In the simulation, it has been notified that the irradiance losses are dependent on the time of a day, sun position, and the rate of created shadow. From the simulated results, annual energy produced and near shading losses in the non-shaded system is 2373 kWh and 0% respectively while in the shaded system, the annual energy produced was 2055 kWh and 2.1% of near shading losses. This undoubtedly disturbs the performance of the power system as well as other related works. Based on the result for this work, shadow affects the performance of PV systems and the rate at which the PV system is affected depends on the shaded area, position, and how much radiation reaches that shaded area. This increases the system’s instability as it can lose its ability to generate power at the maximum due to the user control algorithm as well as degradation of the output that a PV panel can produce. Furthermore, investigations need to be carried out to modify this work. Providers of energy based on solar systems should sensitize shading issues towards their beneficiaries, and make a follow-up to installed systems so that users can give special attention to shading issues while they operate their system. It is recommended to continue this research within Rwandan Solar power plants considered as a case study for more investigation.

Published in International Journal of Sustainable and Green Energy (Volume 10, Issue 2)
DOI 10.11648/j.ijrse.20211002.13
Page(s) 47-62
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2021. Published by Science Publishing Group

Keywords

PV Systems, Shading Effect, Performance of PV Module, PVSYST Simulation

References
[1] Ansari A. & Rafique A. (2011) Generation of Electricity through Solar cell and Thermocouples with selling power back to Grid, 26th IEEEP Students’ Seminar 2011 Pakistan Navy Engineering College National University of Sciences & Technology, 5.
[2] Haukkala T. (2015) Energy Research & Social Science Does the sunshine in the High North? Vested interests as a barrier to solar energy deployment in Finland, Energy Resource and Social Science, 6 (2015), 50–58.
[3] Najafi G., Ghobadian B., Mamat R., Yusaf T., & Azmi W. H. (2015) Solar energy in Iran: Current state and outlook,” Renewable and Sustainable Energy Reviews, 9 (2015), 931–942.
[4] Jäger-Waldau A. (2017) New solar power plants added almost 35% to the world-wide new power generating capacity in 2017.
[5] Masson G. & Kaizuka I. (2017) IEA PVPS Trends 2017 In Photovoltaic Applications.
[6] Distributed Power Africa. (2020) The Future of Solar, PV an excerpts from the DPA BJCC Workshop. Available: https://dpaafrica.com/2020/01/21/the-future-of-solar-pv/.
[7] Al-Shamani A. N., Othman M. Y. H., Mat S., Ruslan M. H., Abed A. M., & Sopian K. (2014) Design & Sizing of Stand-alone Solar Power Systems A house Iraq, Recent Advances in Renewable Energy Sources Design, 145–150.
[8] Sala M., Alcamo G., & Nelli L. C. (2017) Mediterranean Green Buildings & Renewable Energy, Springer.
[9] Bimenyimana S., Norense G., Asemota O., Kemunto M. C., & Li L. (2017) Shading Effects in Photovoltaic Modules: Simulation and Experimental Results, 2nd International Conference on Power and Renewable Energy (ICPRE), 904–909.
[10] Sun Y., Li X., Hong R., & Shen H. (2013) Analysis on the Effect of Shading on the Characteristics of Large-scale on-grid PV System in China,” Energy Power Engineering, 5, 215–218.
[11] Chaudhary A., Gupta S., Pande D., Mahfooz F., & Varshney G. (2015) Effect of Partial Shading on Characteristics of PV panel using Simscape, 5 (10), 85–89.
[12] Hanitsch R. E., Schulz D., & Siegfried U. (2001) Shading Effects on Output Power of Grid Connected Photovoltaic Generator Systems,” Reviews Energy Renewable: Power Engineering, 93–99.
[13] Zhou T. & Sun W. (2014) Study on maximum power point tracking of photovoltaic array in irregular shadow, International Journal of Electrical Power Energy System, 66, 227–234.
[14] Alam K. (2019) Techniques to Mitigate Problem of Partial Shading and Soiling on PV Module: A Review,” International Journal Work, 6 (5), 148–152.
[15] Mohammedi A., Mezzai N., Rekioua D., & Rekioua T. (2014) Impact of shadow on the performances of a domestic photovoltaic pumping system incorporating an MPPT control: A case study in Bejaia, North Algeria, Energy Conversation Management, 84, 20–29, 2014.
[16] Ekpenyong, E. E. &Anyasi, F. I. (2013) Effect of Shading on Photovoltaic Cell, IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE), 8 (2), 1–6.
[17] Sathyanarayana P., Balla R., Lakshmi Sagar P. S., & Kumar G (2015) Effect of Shading on the Performance of Solar PV Panel Energy and Power, 5 (1A), 1–4.
[18] Labouret A. & Villoz M. (2010) Solar Photovoltaic Energy. The Institution of Engineering and Technology.
[19] De Lima L. C., Ferreira L. D. A., Hedler F., & De Lima B. (2017) Development Performance analysis of a grid connected photovoltaic system in northeastern Brazil, Energy Sustainability Development, 37, 79–85.
[20] Kellenberg J. (2015) Utility-Scale Solar Photovoltaic Power Plants, Utility-Scale Solar Power Plants guidebook, International Finance Corporation, 216.
[21] Shoemaker P. (2012) Basics of Photovoltaic (PV) Systems for Grid-Tied Applications.
[22] Kim Y. S. & Winston R. (2013) Power conversion in concentrating photovoltaic systems: central, string, and micro-inverters, John Wiley Sons, 984–992.
[23] Kumar A., Gupta N., & Gupta V. (2017) A Comprehensive Review on Grid-Tied Solar Photovoltaic System, Journal of Green Engineering 7, 213–254.
[24] Pva A. N. (2011) Guide to Interpreting I-V Curve Measurements of PV Arrays, Solmetric.
[25] Al Bashir A., Al-dweri M., Al Ghandoor A., Hammad B., & Al Kouz W. (202) Analysis of Effects of Solar Irradiance, Cell Temperature and Wind Speed on Photovoltaic Systems Performance, International Journal of Energy and Economic Policy, 10 (1), 353–359.
[26] Lappalainen K. & Valkealahti S. (20170 Effects of PV array layout, electrical configuration and geographic orientation on mismatch losses caused by moving clouds, Solar Energy, 144, 548–555.
[27] Teo J. C., Tan R. H. G., & Tan C. (2018) Impact of Partial Shading on the P-V Characteristics and the Maximum Power of a Photovoltaic String, Energies, 11 (1860), 1-22.
[28] International Trace Software (2020) Which factors shall you consider for the installation of photovoltaic panels? Available: https://www.trace-software.com/blog/which-factors-shall-you-consider-for-the-installation-of-photovoltaic-panels/.
[29] Bulanyi P. & Zhang R. (2014) Shading Analysis & Improvement for Distributed Residential Grid- Connected Photovoltaics Systems, The 52nd Annual Conference of the Australian Solar Council, 2014.
[30] Kaushika N. D. & Rai A. K. (2007) An investigation of mismatch losses in solar photovoltaic cell networks, Energies, 32, 755–759.
[31] Fernando L., Villa L., Ho T., Crebier J., & Raison B. (2013) A Power Electronics Equalizer Application for Partially Shaded Photovoltaic Modules,” IEEE Transactions on Industrial Electronics, 60 (3), 1179–1190.
[32] Lorente D. G., Pedrazzi S., Zini G., Rosa A. D., & Tartarini P. (1014) Mismatch losses in PV power plants, Solar Energy, 100, 42–49.
[33] Balasubramanian I. R., Ganesan S. I., & Chilakapati N. (2014) Impact of partial shading on the output power of PV systems under partial shading conditions, Institution of Engineering and Technology Power Electron, 7 (3), 657–666.
[34] Kaushika N. D., Mishra A., & Rai A. K. (2018) Solar Photovoltaics. New Delhi, Springer.
[35] Abu-Rub H., Malinowski., & Al-Haddad K. (2014) Power Electronics for Renewable Energy Systems, Transportation and Industrial Applications, IEEE Press and John Wiley & Sons Ltd.
[36] Muñoz Y., Vargas O., Pinilla G., Vásquez J., & Nariño A. (2017) Sizing and Study of the Energy Production of a Grid-Tied Photovoltaic System Using PVsyst Software, TECCIENCIA, 12 (22), 27–32.
[37] Sharma D. K., Verma V., & Singh A. P. (2014) Review and Analysis of Solar Photovoltaic Softwares, International Journal of Current Engineering and Technology, 4 (2), 725–731.
[38] MERMOUD A., LEJEUNE T. (2010) Partial shadings on PV arrays: by-pass diode benefits analysis, 25th European Photovoltaic Solar Energy Conference. 2010
[39] PVsyst 7. (2020) Performance Ratio, Available: https://www.pvsyst.com/help/index.html?performance_ratio.htm.
Cite This Article
  • APA Style

    Dushengere Bernadette, Maurice Twizerimana, Alexis Bakundukize, Bizabakoraho Jean Pierre, Nsekambabaye Theoneste. (2021). Analysis of Shading Effects in Solar PV System. International Journal of Sustainable and Green Energy, 10(2), 47-62. https://doi.org/10.11648/j.ijrse.20211002.13

    Copy | Download

    ACS Style

    Dushengere Bernadette; Maurice Twizerimana; Alexis Bakundukize; Bizabakoraho Jean Pierre; Nsekambabaye Theoneste. Analysis of Shading Effects in Solar PV System. Int. J. Sustain. Green Energy 2021, 10(2), 47-62. doi: 10.11648/j.ijrse.20211002.13

    Copy | Download

    AMA Style

    Dushengere Bernadette, Maurice Twizerimana, Alexis Bakundukize, Bizabakoraho Jean Pierre, Nsekambabaye Theoneste. Analysis of Shading Effects in Solar PV System. Int J Sustain Green Energy. 2021;10(2):47-62. doi: 10.11648/j.ijrse.20211002.13

    Copy | Download

  • @article{10.11648/j.ijrse.20211002.13,
      author = {Dushengere Bernadette and Maurice Twizerimana and Alexis Bakundukize and Bizabakoraho Jean Pierre and Nsekambabaye Theoneste},
      title = {Analysis of Shading Effects in Solar PV System},
      journal = {International Journal of Sustainable and Green Energy},
      volume = {10},
      number = {2},
      pages = {47-62},
      doi = {10.11648/j.ijrse.20211002.13},
      url = {https://doi.org/10.11648/j.ijrse.20211002.13},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ijrse.20211002.13},
      abstract = {Due to its advantages, the use of clean energy in general and especially solar PV systems offer a great solution to problems that people face in their everyday life. Generation of energy using solar PV system technology is cheaper and clean technology compared to one of the fossil fuels. Aside from its advantages, this technology still has some drawbacks that affect its performance where the ones caused by shadows are considered as one of the big problems. This research work showed laboratory experiments and simulations to see how the system is affected by shading where a 1.5 kWp PV system has been used for the study. The system has been simulated with PVsyst (7.0.6 version) and experimented within the University of Rwanda/ African Center of Excellence in Energy Studies for Sustainable Development (UR/ACE-ESD) High E-Tech Smart Grid Laboratory. Laboratory experiments showed that whatever shade is applied to the system, the DC voltage and current change (increases or decrease) and DC power decreases. In the simulation, it has been notified that the irradiance losses are dependent on the time of a day, sun position, and the rate of created shadow. From the simulated results, annual energy produced and near shading losses in the non-shaded system is 2373 kWh and 0% respectively while in the shaded system, the annual energy produced was 2055 kWh and 2.1% of near shading losses. This undoubtedly disturbs the performance of the power system as well as other related works. Based on the result for this work, shadow affects the performance of PV systems and the rate at which the PV system is affected depends on the shaded area, position, and how much radiation reaches that shaded area. This increases the system’s instability as it can lose its ability to generate power at the maximum due to the user control algorithm as well as degradation of the output that a PV panel can produce. Furthermore, investigations need to be carried out to modify this work. Providers of energy based on solar systems should sensitize shading issues towards their beneficiaries, and make a follow-up to installed systems so that users can give special attention to shading issues while they operate their system. It is recommended to continue this research within Rwandan Solar power plants considered as a case study for more investigation.},
     year = {2021}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Analysis of Shading Effects in Solar PV System
    AU  - Dushengere Bernadette
    AU  - Maurice Twizerimana
    AU  - Alexis Bakundukize
    AU  - Bizabakoraho Jean Pierre
    AU  - Nsekambabaye Theoneste
    Y1  - 2021/05/08
    PY  - 2021
    N1  - https://doi.org/10.11648/j.ijrse.20211002.13
    DO  - 10.11648/j.ijrse.20211002.13
    T2  - International Journal of Sustainable and Green Energy
    JF  - International Journal of Sustainable and Green Energy
    JO  - International Journal of Sustainable and Green Energy
    SP  - 47
    EP  - 62
    PB  - Science Publishing Group
    SN  - 2575-1549
    UR  - https://doi.org/10.11648/j.ijrse.20211002.13
    AB  - Due to its advantages, the use of clean energy in general and especially solar PV systems offer a great solution to problems that people face in their everyday life. Generation of energy using solar PV system technology is cheaper and clean technology compared to one of the fossil fuels. Aside from its advantages, this technology still has some drawbacks that affect its performance where the ones caused by shadows are considered as one of the big problems. This research work showed laboratory experiments and simulations to see how the system is affected by shading where a 1.5 kWp PV system has been used for the study. The system has been simulated with PVsyst (7.0.6 version) and experimented within the University of Rwanda/ African Center of Excellence in Energy Studies for Sustainable Development (UR/ACE-ESD) High E-Tech Smart Grid Laboratory. Laboratory experiments showed that whatever shade is applied to the system, the DC voltage and current change (increases or decrease) and DC power decreases. In the simulation, it has been notified that the irradiance losses are dependent on the time of a day, sun position, and the rate of created shadow. From the simulated results, annual energy produced and near shading losses in the non-shaded system is 2373 kWh and 0% respectively while in the shaded system, the annual energy produced was 2055 kWh and 2.1% of near shading losses. This undoubtedly disturbs the performance of the power system as well as other related works. Based on the result for this work, shadow affects the performance of PV systems and the rate at which the PV system is affected depends on the shaded area, position, and how much radiation reaches that shaded area. This increases the system’s instability as it can lose its ability to generate power at the maximum due to the user control algorithm as well as degradation of the output that a PV panel can produce. Furthermore, investigations need to be carried out to modify this work. Providers of energy based on solar systems should sensitize shading issues towards their beneficiaries, and make a follow-up to installed systems so that users can give special attention to shading issues while they operate their system. It is recommended to continue this research within Rwandan Solar power plants considered as a case study for more investigation.
    VL  - 10
    IS  - 2
    ER  - 

    Copy | Download

Author Information
  • African Centre of Excellence in Energy for Sustainable Development (ACE-ESD), College of Science and Technology, University of Rwanda, Kigali, Rwanda

  • African Centre of Excellence in Energy for Sustainable Development (ACE-ESD), College of Science and Technology, University of Rwanda, Kigali, Rwanda

  • African Centre of Excellence in Energy for Sustainable Development (ACE-ESD), College of Science and Technology, University of Rwanda, Kigali, Rwanda

  • African Centre of Excellence in Energy for Sustainable Development (ACE-ESD), College of Science and Technology, University of Rwanda, Kigali, Rwanda

  • African Centre of Excellence in Energy for Sustainable Development (ACE-ESD), College of Science and Technology, University of Rwanda, Kigali, Rwanda

  • Sections