Abstract

Taguchi’s L16 orthogonal array in the study of removal of total phenols using advanced oxidation processes was efficient. In the statistical assessment, the input variables obtained as significant through ANOVA were: hydrogen peroxide (F = 10.0924 and p-value = 5.02) and ozone (F = 3.8686 and p-value = 14.39). In this assessment, the best experimental condition for the removal of total phenols is 100%. The following factors must therefore be adjusted: hydrogen peroxide = 38, 7g and ozone flow = 3 L/h.

Published in American Journal of Theoretical and Applied Statistics (Volume 2, Issue 6)
DOI 10.11648/j.ajtas.20130206.22
Page(s) 243-247
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2013. Published by Science Publishing Group

Keywords

Taguchi Method, Advanced Oxidation Processes

References
[1] Arslan-Alaton, I., Degradation of a commercial textile biocide with advanced oxidation process and ozone. Journal of Environmental Management, 82, 145-154, 2007.
[2] Borghei, S. M., Hosseini, S. H., The treatment of phenolic wastewater using a moving bed biofilm reactor. Process Biochemistry, 39, 1177-1181, 2004.
[3] Kennedy, L., Vijaya, J., Kayalvizhi, K., Sekaran, G., Adsorption of phenol from aqueous solutions using mesoporous carbon prepared by two-stage process. Chemical Engineering Journal, 132, 279-287, 2007.
[4] Jiang, C., Pang, S., Ouyang, F., M. A, J., Jiang, J., A new insight into Fenton and Fenton-like processes for water treatment. Journal of Hazardous Materials, 174, 813–817, 2010.
[5] Mahamuni, N. N., Adewuyi, Y. G., Advanced oxidation processes (AOPs) involving ultrasound for waste water treatment: A review with emphasis on cost estimation. Ultrasonics Sonochemistry, 17, 990–1003, 2010.
[6] Agarwal, S., Ferreira, A. E., Reis, M. T. A., Ismael, M. R. C., Ferreira, L. M., Machado, R. M., Carvalho, J. M.R., A study on a combined process for the treatment of phenolic resin plant effluents. Journal of Hazardous Materials, 169, 659–666, 2009.
[7] Lanouette, K. H., Treatment of phenolic wastes. Chemical Engineering, 84, 99–106, 1977.
[8] Kajitvichyanukul, P., LU, M. C., Jamoresan, A., Formaldehyde degradation in the presence of methanol by photo-Fenton process. Journal of Environmental Management, 86, 545–553, 2008.
[9] Pera-Titus, M. P., Molina, V. M., Baños, M. A., Gimenez, J., Esplugas, S., Degradation of chlorophenols by means of advanced oxidation processes: a general review. Applied Catalysis B: Environmental, 47, 219–256, 2004.
[10] Epa- U.S., Environmental Protection Agency. Toxicological review of phenol, 2002. http://www.epa.gov/IRIS/toxreviews/0088-tr.pdf. Accessed in: 2011, March, 20.
[11] Doocey, D .J., Sharratt, P. N., Cundy, C. S., Plaisted, R. J., Zeolite-Mediated advanced oxidation of model chlorinated phenolic aqueous waste Part 2: Solid Phase Catalysis. Institution of Chemical Engineers, 82, 359-364, 2004.
[12] Gogate, P. R., Treatment of wastewater streams containing phenolic compounds using hybrid techniques bades on cavitation: A review of the G status and the way forward.Ultrasonics Sonochemistry, 5, 1–15, 2008.
[13] Neamtu, M., Yediler, A., Siminiceanu, I., Kettrup, A., Oxidation of commercial reactive azo dye aqueous solutions by the photo-Fenton and Fenton-like processes. Journal of Photochemistry and Photobiology A: Chemistry, 161, 87–93, 2003.
[14] Segura,Y., Molina, R., Martínez, F., Melero, J. A., Integrated heterogeneous sono–photo Fenton processes for the degradation of phenolic aqueous solutions. Ultrasonics Sonochemistry, 16, 417–424, 2009.
[15] Oller, I., Malato, S., Sanchez-Perez, J. A., Combination of a advanced oxidation process and biological treatments for waste water decontamination: A review. Science of the total environment, 409, 4141-4166, 2011.
[16] Oliver, J. H., Hynook, K., Pen-Chi, C., Decolorization of wastewater, Crit. Rev .Environmental Science Technology, 30, 499–505, 2000.
[17] Khataee, A. R., Vatanpour, V., Ghadim, A. R. A., Decolorization of C.I. Acid Blue 9 solution by UV/Nano-TiO2, Fenton, Fenton-like, electro-Fenton and electrocoagulation processes: A comparative study. Journal of Hazardous Materials, 161, 1225–1233, 2009.
[18] Kusic, H., Koprivanac, N., Srsan, L., Azo dye degradation using Fenton type processes assisted by UV irradiation: A kinetic study. Journal of photochemistry and photobiology A: Chemistry, 181, 195-202, 2007.
[19] Fatta-Kasinos, D., Vasquez, M. I., Kümerer, K., Transformation products of pharmaceuticals in surface Waters and wastewater formed during photolysis and advanced oxidation process – Degradation, elucidation of byproducts and assessment of their biologycal potency: Review. Chemosphere, 85, 693-709, 2011.
[20] Hsu, Y., Yang, H., Chen, J., The enhancement of the biodegradability of phenolic solution using preozonation based on high ozone utilization. Chemosphere, 56, 149-158, 2004.
[21] Wu, J., Rudy, K., Saprk, J., Oxidation of aqueous phenol by ozone and peroxidase. Adavances in Environmental Research, 4, 339-346, 2000.
[22] iang, C., Pang, S., Ouyang, F., M. A, J., Jiang, J. A new insight into Fenton and Fenton-like processes for water treatment. Journal of Hazardous Materials, 174, 813–817, 2010.
[23] Neyens, E., Bayens, J., A review of classic Fenton’s peroxidation as an advanced oxidation technique. Journal of Hazardous Materials, 98, 33–50, 2003.
[24] Li, D., Tong, T. Y., Huang, J., Ding, L., Zhong, Y., Zeng, D., Yan, P., First observation of tetranitro iron (II) phthalocyanine catalyzed oxidation of phenolic pollutant assisted with 4-aminoantipyrine using dioxygen as oxidant. Journal of Molecular Catalysis A: Chemical, 345, 108-116, 2011.
[25] Phadke, M. S. (1989): Quality engineering using robust design. Prentice Hall press.
Cite This Article
  • APA Style

    Ana Paula Barbosa Rodrigues de Freitas, Leandro Valim de Freitas, Hélcio José Izário Filho, Messias Borges Silva. (2013). Phenol Removal via Advanced Oxidative Processes (O3/Photo-Fenton) and Chemometrics. American Journal of Theoretical and Applied Statistics, 2(6), 243-247. https://doi.org/10.11648/j.ajtas.20130206.22

    Copy | Download

    ACS Style

    Ana Paula Barbosa Rodrigues de Freitas; Leandro Valim de Freitas; Hélcio José Izário Filho; Messias Borges Silva. Phenol Removal via Advanced Oxidative Processes (O3/Photo-Fenton) and Chemometrics. Am. J. Theor. Appl. Stat. 2013, 2(6), 243-247. doi: 10.11648/j.ajtas.20130206.22

    Copy | Download

    AMA Style

    Ana Paula Barbosa Rodrigues de Freitas, Leandro Valim de Freitas, Hélcio José Izário Filho, Messias Borges Silva. Phenol Removal via Advanced Oxidative Processes (O3/Photo-Fenton) and Chemometrics. Am J Theor Appl Stat. 2013;2(6):243-247. doi: 10.11648/j.ajtas.20130206.22

    Copy | Download

  • @article{10.11648/j.ajtas.20130206.22,
      author = {Ana Paula Barbosa Rodrigues de Freitas and Leandro Valim de Freitas and Hélcio José Izário Filho and Messias Borges Silva},
      title = {Phenol Removal via Advanced Oxidative Processes (O3/Photo-Fenton) and Chemometrics},
      journal = {American Journal of Theoretical and Applied Statistics},
      volume = {2},
      number = {6},
      pages = {243-247},
      doi = {10.11648/j.ajtas.20130206.22},
      url = {https://doi.org/10.11648/j.ajtas.20130206.22},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ajtas.20130206.22},
      abstract = {Taguchi’s L16 orthogonal array in the study of removal of total phenols using advanced oxidation processes was efficient. In the statistical assessment, the input variables obtained as significant through ANOVA were: hydrogen peroxide (F = 10.0924 and p-value = 5.02) and ozone (F = 3.8686 and p-value = 14.39). In this assessment, the best experimental condition for the removal of total phenols is 100%. The following factors must therefore be adjusted: hydrogen peroxide = 38, 7g and ozone flow = 3 L/h.},
     year = {2013}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Phenol Removal via Advanced Oxidative Processes (O3/Photo-Fenton) and Chemometrics
    AU  - Ana Paula Barbosa Rodrigues de Freitas
    AU  - Leandro Valim de Freitas
    AU  - Hélcio José Izário Filho
    AU  - Messias Borges Silva
    Y1  - 2013/12/10
    PY  - 2013
    N1  - https://doi.org/10.11648/j.ajtas.20130206.22
    DO  - 10.11648/j.ajtas.20130206.22
    T2  - American Journal of Theoretical and Applied Statistics
    JF  - American Journal of Theoretical and Applied Statistics
    JO  - American Journal of Theoretical and Applied Statistics
    SP  - 243
    EP  - 247
    PB  - Science Publishing Group
    SN  - 2326-9006
    UR  - https://doi.org/10.11648/j.ajtas.20130206.22
    AB  - Taguchi’s L16 orthogonal array in the study of removal of total phenols using advanced oxidation processes was efficient. In the statistical assessment, the input variables obtained as significant through ANOVA were: hydrogen peroxide (F = 10.0924 and p-value = 5.02) and ozone (F = 3.8686 and p-value = 14.39). In this assessment, the best experimental condition for the removal of total phenols is 100%. The following factors must therefore be adjusted: hydrogen peroxide = 38, 7g and ozone flow = 3 L/h.
    VL  - 2
    IS  - 6
    ER  - 

    Copy | Download

Author Information
  • Production Engineering Department, S?o Paulo State University (UNESP), Guaratinguetá, Lorena, Brazil

  • Production Engineering Department, S?o Paulo State University (UNESP), Guaratinguetá, Lorena, Brazil

  • Chemical Engineering Department, S?o Paulo University (USP), Lorena, Brazil

  • Production Engineering Department, S?o Paulo State University (UNESP), Guaratinguetá, Lorena, Brazil

  • Sections